Please use this identifier to cite or link to this item: http://dx.doi.org/10.15480/882.33
Title: Die Beeinflussung der Meßabweichung von Feldsonden und Stromzangen durch reale Umgebungsbedingungen
Other Titles: The influence of measurement uncertainties of field sensors and current probes under the condition of real environments
Language: German
Authors: Monien, Georg
Thesis Advisor: Singer, Hermann Prof. Dr.
Keywords: Messabweichung;Messunsicherheit;elektromagnetische Felder;numerische Simulation;Momentenmethode;Antennen;Stromzangen;Measurement error;measurement uncertainty;electromagnetic fields;numerical simulation;method of moments;antennas;current probes
Issue Date: 2003
Publisher Source: Die Beeinflussung der Meßabweichung von Feldsonden und Stromzangen durch reale Umgebungsbedingungen / von Georg Monien. Hamburg-Harburg, Techn. Univ., Diss., 2002.
Abstract (german): Die Messung elektromagnetischer Felder und hochfrequenter Leitungsströme wird durch eine Vielzahl unterschiedlicher Faktoren beeinflusst und kann zu einer Messabweichung führen, die in Form einer Messunsicherheit nach DIN 1319 Teil des Messergebnisses ist. Systematische Untersuchungen über mögliche Messabweichungen sind messtechnisch wie auch analytisch nur scher durchzuführen und erst in neuerer Zeit auf Basis numerischer Methoden einer Analyse zugänglich. Im Rahmen dieser Arbeit werden Feldsonden und Stromzangen mit Hilfe der Momentenmethode numerisch modelliert. Die resultierende Messabweichung wie auch die Rückwirkung auf die Messumgebung werden dabei in Abhängigkeit vom Sondentyp, der Feldanregung und benachbarter Streustrukturen bestimmt. Es werden Kennwerte für Feldsonden und Stromzangen erarbeitet, mit denen es möglich ist, quantitative Aussagen über die Messabweichung zu machen.
Abstract (english): The measurement of electromagnetic fields and high-frequency conducted currents is influenced by a great number of factors. This may lead to a measurement error which is part of the measurement result in the form of a measurement uncertainty according to DIN 1319. Systematic investigations of possible measurement errors have been difficult technically as well as analytically. Only lately have analyses been possible on the basis of numerical methods. In this thesis the method of moments is used to model field sensors and current probes numerically. The resulting measurement error as well as the influence on the measurement environment are determined depending in relation to sensor type, field source and close scattering structures. Characteristic values for field sensors and current probes are found which allow the quantitative prediction of measurement errors.
URI: http://tubdok.tub.tuhh.de/handle/11420/35
URN: urn:nbn:de:gbv:830-opus-754
DOI: 10.15480/882.33
Institute: Theoretische Elektrotechnik E-18
Electromagnetic Theory E-18 (Theoretical Electrical Engineering)
Faculty: Elektrotechnik und Informationstechnik
Document Type: Dissertation
Appears in Collections:tub.dok

Files in This Item:
File Description SizeFormat 
Dissertation_Monien_1203.pdf2,15 MBAdobe PDFView/Open

Items in tub.dok are protected by copyright, with all rights reserved, unless otherwise indicated.